Vin Bio Care

Refrigerated Centrifuges Manufacturers

Refrigerated Centrifuges Manufacturers

These Plus series Refrigerated Centrifuges are designed for centrifugation of temperature sensitive material and find application in routine and research work in auxiliary laboratories in industry, Educational & Research institutions, Bio Technology, Medical Laboratories, Hospitals, Blood Banks, Pharmaceutical & Clinical research laboratories.

All the centrifuges have rust proof, easy to clean Stainless Steel centrifuge inner chamber with steel guard. A wide variety of swing out and angle rotors with a choice of reduction adaptors make these units truly versatile.

Users can select models as per their requirements from high volume low speed Centrifuges (C-23 Plus, CPR-23 Plus), low volume high speed centrifuges (C-24 Plus, CPR-24 Plus) in table top design & compact high-speed high volume (C-30 Plus, CPR-30 Plus) floor standing centrifuges.

 Table Top ModelsFloor Models
High Volume Low SpeedLow Volume High SpeedHigh Volume High Speed
C-23 PlusCPR-23 PlusC-24 PlusCPR-24 PlusCPR-24i PlusC-30 PlusCPR-30 Plus
Programable compensation for true sample temperature
Pre cooling
Acceleration Profileslow, high9low, high99low, high9
Deceleration ProfilesCoasting, low, high9 & CoastingCoasting, low, high9 & Coasting9 & CoastingCoasting, low, high9 & Coasting
Fast Spin
Calibration window on lid for speed
DisplayLEDLCDLEDLCDLCDLEDLCD
Control CommunicationDigitalDigitalDigitalDigitalDigitalDigitalDigital
Self-Diagnostics of errors
Parameters setting switchesFeather touch keysBi-directional encoderFeather touch keysBi-directional encoderBi-directional encoderFeather touch keysBi-directional encoder
Brushless motor with frequency drive
Inverter fault detection with auto shut down
CFC free refrigeration system
No. of Programs99999999
Last set parameters recall
Choice of rpm / rcf settingRPMRPM / RCFRPMRPM / RCFRPM / RCFRPMRPM / RCF
Temperature display°C°C / °F°C°C / °F°C / °F°C°C / °F
Digital countdown timer 0-99 min & Continuous run
Log of cumulative run time
Automatic Rotor Identification
Motor overload protection
Emergency lid lock release
Imbalance detection with centrifugation cut off
Password protection
Gas Hinge to prevent door falling
Technical Data
Models C-23 Plus CPR-23 PlusC-24 Plus CPR-24 PlusCPR-24i PlusC-30 Plus CPR-30 Plus
Max. Speedrpm7000200002000020000
Max. RCFg’7400375703757037570
Max. Tube Sizeml250100250250
Max. Capacityml120040010001200
*Lowest Temp.°C– 8– 8– 10– 8
#Noise ≤ 60 dB≤ 60 dB≤ 60 dB≤ 60 dB
W x D x Hmm800 x 6OO x 500775 x 575 x 475830 x 650 x 500660 x 765 x 945
Voltage StabilizermodelVS-03VS-03VS-03VS-03

Supply: 220-240 Volts 50 Hz single Phase.
*Note Depending on capacity, type of rotor, centrifugeation speed,
ambient temperature and othe process parameters.
#Note : Measure as per standard protocol

Rotor Heads Listing
ModelsCapacityContainerC-23 PlusCPR-23 PlusC-24 PlusCPR-24 PlusCPR-24i PlusC-30 PlusCPR-30 Plus
Speed (rpm)RCF ‘g’Speed (rpm)RCF ‘g’Speed (rpm)RCF ‘g’Speed (rpm)RCF ‘g’
Swing out Heads (with graduated glass tubes)
R-230 M + R-231 M4 x 200 MLGLASS5100450045003500
R-234 M4 x 250 MLPLASTIC550050705500507045003500
R-235 MB X MICR0TIT0R96 WELL320014703200147032001470
R-230 BM + R-233 BM108 x 5ML (RIA)RIA PLASTIC TUBES5100398045003500
R-240 M16 x 50 MLFALCON32001775
R-240 AM32 x 15 MLFALCON32001775
R-246 AM4 x 25 MLGLASS110001218011000121801100012180
Angle Heads (with polypropylene tubes)
R-236 M6 x 200 MLPLASTIC7000740070007400
R-237 M8 x 100 MLPLASTIC7000740070007400
R-238 M12 x 50 MLPLASTIC7000740070007400
R-239 M36 x 15 MLPLASTIC7000740070007400
R-241 M4 x 100 MLPLASTIC145002398014500239801450023980
R-243 M8 x 25 MLPLASTIC180003115018000311501800031150
R-244 M12 x 15 MLPLASTIC180003115018000311501800031150
R-247 M8 x 50 MLPLASTIC160002862016000286201600028620
R-248 M24 x 1.5 MLPLASTIC200003757020000375702000037570
R-249 M6 strips of 8 x 0.2 mlPLASTIC110001218011000121801100012180
R-250 M48×1.5 MLPLASTIC160002862016000286201600028620
Angle Heads suitable for Falcon Tubes (without tubes)
R-238 MF12 x 50 MLFALCON7000740070007400
R-239 MF24 x 15 MLFALCON7000740070007400
R-244 MF12 x 15 MLFALCON110001461011000146101100014610
R-247 MF8 x 50 MLFALCON110001461011000146101100014610
Reduction Adaptors for Swing Out Head Model R-230 M + R-231 M
Suitable for Glass Tubes (with tubes)
ModelsTube CapacityNo. of tubes per AdaptorTotal No. of Tubes
RA-2311100 ml14
RA-231 250 ml14
RA-231330 ml312
RA-231415 ml728
Suitable for Vacutainer Tubes (without tubes)
RA-2315Upto 4 ml (100 mm long)624
RA-2316Upto 10ml (100 mm long)520
RA-2317Upto 5ml (75 mm long)624

Refrigerated Centrifuges

Refrigerated Centrifuges